Dynanet
Dynanet
The Dynanet voice interface units are designed to provide voice interfaces to the 2048 kbit/s transmission systems with the Nokia Dynanet family of products.
Dynanet
The change-over equipment is to provide an alternative transmission path in a case of a line failure.
Dynanet
Nokia’s higher order digital multiplex equipment multiplexes four tributary signals into the main system, and vice-versa.
Dynanet
The Nokia DF optical line equipment provides digital signal transmission on optical fibres at bit rates of 2, 8 and 34 Mbit/s.
Dynanet
Nokia ISDN interface cards provide the ability for carriers to offer cost-efficient ISDN service.
Dynanet
The Dynanet data interface units are designed to provide data interfaces to the 2048 kbit/s transmission systems with the Nokia Dynanet family of products.
Dynanet
TPS64 is intended to be used to detect supply failures in the power lines and send the on/off commands and alarm information using a digital telecommunication network.
Dynanet
ACM2 is the 2 Mbit/s multiplexer optimised for POTS use. It has up to 120 subscriber interfaces in one 19” subrack.
Dynanet
Nokia DB2 performs branching equipment functions and can be controlled dynamically.
Dynanet
DN2 dynamic node equipment provides an efficient three-inone node for network flexibility and reliability.
Dynanet
Nokia DM2 performs the functions of dynamically controllable primary multiplex equipment.
> Haut de page
---------------------------------------------------------------------------------------------------------------------------
Mechanics
Mechanics
Repeater mechanics are used in copper-wire systems in outdoor installations with DL2E and SHDSL DSL2i line-repeaters.
Mechanics
TPS64 5-slot Nokia Dynanet Mechanics (NDM) subrack can house 4 plug-in units (25 mm/5T) + 1 Power Unit (39 mm/8T).
Mechanics
The 8-slot subrack can house 7 plug-in units (25 mm/5 T) + 1 Power Unit (39 mm/8T).
Mechanics
The subrack can house 16 plug-in units (25 mm/5 T) + 1 Power Unit (39 mm/8T).
Mechanics
The subrack can house 16 plug-in units (25 mm/5 T) + 1 Power Unit (39 mm/8T).
> Haut de page
----------------------------------------------------------------------------------------------------------------------------
Power Supply
Power Supply
Rack specific DC power supply adapter (with 6 outputs and two 6mm2 battery inputs) is designed primarily for ACM2/ ACM4 systems.
Power Supply
NDM AC/DC Unit (NAU) is an AC/DC Power plug-in unit for NDM Subracks.
Power Supply
NDM DC Unit (NDU) is a DC/DC Power plug-in unit for NDM Subracks.
Power Supply
Rack Power Module 2x10A (RPM 2x10A) is a plug-in power module to be used in conjunction with the RPSA to supply an NDM subrack that has NDA as input unit.
Power Supply
RPSA is a rack specific interface host element and a connection point for battery voltages when subracks are fed with a nominal battery voltage of 24/48/60 V (range -20& -75 VDC).
Power Supply
NDM DC Adapter (NDA) is a DC Power feeding plug-in adapter (unit) to subrack (Used with RPSA and RPM).
Power Supply
Rack Alarm Module (ALM) is a plug-in alarm unit, which will be used if Rack alarms are requested.
> Haut de page
---------------------------------------------------------------------------------------------------------------------------
Copper Access Equipments (Modems)
Copper Access Equipments
The Nokia DNT2M-G-mp is a 2 Mbit/s Network Terminal (Mini Node) for E1 transport, G.703/G.704 (HDB3 coding) over twisted copper pairs.
Copper Access Equipments
The Nokia DNT2M-G-sp is a 2 Mbit/s network terminal for E1 transport, G.703/G.704 (HDB3 coding) over twisted copper pairs.
Copper Access Equipments
The interface units are suitable for the DNT2Mi-sp, DNT2Mi-mp, DNT2M-G-sp and DNT2M-G-mp.
Copper Access Equipments
The Nokia DSL2i is a nx64 kbit/s SHDSL regenerator (repeater) which enables the use of exceptionally long local loops to connect remote users via a SHDSL line system to the transmission network.
Copper Access Equipments
The Nokia ACL8i consists of four SHDSL line terminals for data transmission over twisted copper pairs.
Copper Access Equipments
Nokia ACL2ti is a nx64 kbit/s SHDSL line terminal for data transmission over twisted copper pairs.
Copper Access Equipments
Nokia ACL2i is an ITU-T compliant SHDSL Line Terminal for transport over the subscriber loop using one, or two, twisted copper pairs.
Copper Access Equipments
Nokia DNT2Mi-fp530 (Data Network Terminal) provides data transport over the local loop to the central site.
Copper Access Equipments
Nokia DNT2Mi-fp (Data Network Terminal) provides voice and data transport over the local loop to the 2M service at the central site.
Copper Access Equipments
The DNT2Mi-mp (multiport) is an ITU-T compliant SHDSL Network Terminal (Mini Node) for nx64kbit/s (up to 2Mbit/s) transport over the subscriber loop using one, or two, twisted copper pairs.
Copper Access Equipments
The DNT2Mi-sp (single port) is an ITU-T compliant SHDSL Network Terminal for nx64kbit/s (up to 2Mbit/s) transport over the subscriber loop using one, or two, twisted copper pairs.
> Haut de page
---------------------------------------------------------------------------------------------------------------------------
TDMoP
TDMoP
TDM over Packet solution provide an easy way to utilize packet network for transporting existing legacy TDM traffic.
> Haut de page